Research on Reliability of PLC Automatic Control System


The reliability problem of the automatic control system has been studied in depth, and a method to improve the reliability of the system is proposed. Practice has proved that the adoption of these methods is effective in improving the reliability of the system.

1 Introduction

The programmable controller is widely used in the industrial control field due to its strong anti-interference ability, high reliability, simple programming and high performance-price ratio.

As the central control unit, the industrial year machine is equipped with configuration software. It uses a large-screen real-time monitoring interface to realize dynamic display, data modification, fault diagnosis and automatic alarm of each control point. It can also display the historical event record of the query. Accumulated running time of components, process flow chart of each device, structure diagram of each device, etc. The serial communication mode is used for data exchange between the central control unit and the lower-position PLC. Usually, the 485 twisted pair communication mode is selected within 1000m, the optical fiber communication can be selected at a longer distance, and the wireless communication mode can be selected for a longer distance. The lower computer selects PLC control. According to the number of control objects, the range of control objects can be controlled by one or more PLCs. The data exchange between PLCs uses internal link registers to realize data exchange and sharing. Because PLC has high reliability for on-site real-time monitoring, and programming is simple and flexible, it has received more and more attention.

2. The main reason for the decrease in control system reliability

Although the industrial control unit and the programmable controller itself have high reliability, if the switching signal input to the PLC is wrong, the analog signal has a large deviation, and the actuator controlled by the PLC output port does not act as required. These can make the control process go wrong, resulting in irreparable economic losses.

The main reasons that affect the input of the PLC signal to the field are:

1) causing short-circuit or open circuit of the transmission signal line (due to mechanical pull, the line itself is aging, especially the rat), when the transmission signal line fails, the field signal cannot be transmitted to the PLC, causing control error;

2) The mechanical contact is shaken. Although the field contact is only closed once, the PLC thinks that it has been closed many times. Although the hardware adds a filter circuit, the software adds a differential instruction. However, since the PLC scan cycle is too short, it may still count, accumulate, An error occurred in the instruction such as shifting, and an error control result occurred;

3) On-site transmitter, the mechanical switch itself is faulty. If the contact is not good, the transmitter will reflect that the non-electricity deviation of the site is large or cannot work normally. These faults will also make the control system not work properly.

The main reasons that affect the execution of the agency are:

1) The contact of the control load cannot be reliably operated, and the PLC issues an action command, but the actuator does not act as required;

2) Control the inverter to start, due to the fault of the inverter itself, the motor with the inverter does not work as required;

3) All kinds of electric valve and solenoid valve can't be opened, the switch can't be closed, because the actuator can't operate according to PLC's control requirements, the system can't work normally, and the system reliability is reduced. In order to improve the reliability of the entire control system, it is necessary to improve the reliability of the input signal and the accuracy of the actuator action. Otherwise, the PLC should be able to find the problem in time, and prompt the operator with an alarm method such as sound and light to eliminate the fault as soon as possible and make the system safe. Work reliably and correctly.

3. Well-designed fault alarm system

In the design of the automatic control system, we designed a three-level fault display alarm system. The first level is set on the control panel of each control panel. The indicator light indicates the normal operation and fault condition of the equipment. When the equipment is in normal operation, the corresponding indicator light is on. The indicator flashes at 1 Hz when the device is faulty.

In order to prevent the lamp bulb from being damaged, the device's working condition cannot be correctly reflected. The fault reset/light test button is specially set. When the system is running for any time, press the button continuously. All the indicators should be lit. If there is an indication, etc. If the indicator light is broken, it should be replaced immediately. After the button is reset, the indicator still displays the working status of the device according to the original working status.

Next page

Hot Pipette Tips

The commonly used Pipette kits are mainly composed of a pipette and a pipette tip. The pipette tip is a single empty
Cavity reservoir; the pipette uses the principle of air displacement and controls the maximum displacement of the piston by rotating a screw with an ultra-fine thread
displacement, and then control the amount of liquid suction. There are the following problems when using the above kit for suction: 1. The suction volume is controlled by the pipette
After the pipette is sterilized or used for a period of time, it is easy to cause "hidden" failures, which cause the operator to be difficult to detect.
The actual suction volume is inaccurate, and it needs to be adjusted frequently, and the operation is cumbersome and time-consuming; 2. To improve the pipetting accuracy, the operator's
The operation requirements are high, and it is easily affected by factors such as the suction speed, the depth of the tip below the liquid level, and the inclination angle of the pipette.
The actual suction volume will be heard; 3. The actual suction volume will be affected because the suction head cover is not tight and leaking, and it will not be easily detected; 4.
When performing experiments that require high accuracy, such as analysis, in the operation of equal volume aspiration of liquids with different densities, the actual
The actual suction volume will be affected by the density itself; 5. In order to improve the accuracy, this type of pipette needs to carry out high
Cost-optimized design results in extremely high pipette costs.

1000 ul pipette tips,200ul pipette tips,10ul pipette tips,low retention pipette tips

Yong Yue Medical Technology(Kunshan) Co.,Ltd , https://www.yypcrtube.com