Calculation of RO System Cleaning Tank Volume

The cleaning tank of the reverse osmosis system is required to be protected against corrosion. The material may be glass fiber reinforced plastic, polyvinyl chloride plastic, or steel tank lined rubber. Due to the specific temperature requirements of RO membranes, in some particularly cold or hot areas, the installation of heating or cooling devices inside the enclosure should be considered. General requirements for cleaning temperature not less than 15 °C, because the temperature is low, it will affect the cleaning effect.

When determining the volume of the cleaning tank, the volume of the pressure vessel, the volume of the security filter, the volume of the circulation pipe, etc. should be considered.

For example: The RO membrane module of a factory adopts a 6-3 arrangement, that is, there are six 8-inch membrane modules in the first stage, three 8-inch membrane modules in the second stage, and six 40-inch membranes in each membrane module. element.

The cleaning tank volume can be calculated as follows:
1) Each pressure vessel volume:
V1=1/4*Ï€*D2*L=3.14/4*[(25.4*8)/1000]2*6=0.1884m3
9 pressure vessel volumes:
V2=0.1884*9=1.6956m3
Assuming that the membrane element occupies 30% of the pressure vessel volume, the volume of water stored in the 9 pressure vessels is:
V3=1.6956*70%=1.1869m3
2) The length of water stored in the pipeline is 50m long (φ89*3.5 lining hose):
V4=1/4*Ï€*D2*L=3.14/4*0.0822*50=0.264m3
3) With φ600 and effective height of 1.3m, the volume of water stored in the security filter is:
V5=1/4*Ï€*D2*H=3.14/4*0.62*1.3=0.3674m3
With a filter that accounts for 5% of the filter volume, the volume of water stored in the filter is:
V6=0.3674*95%=0.349m3
4) Total volume:
V= V3+V4+V6=1.1869+0.264+0.349=1.8m3
Taking into account unforeseen factors, the total volume is multiplied by a factor of 1.2.
V'=1.2V=1.2*1.8=2.16m3
Considering the cleaning cycle, the cleaning tank should have a storage volume of 0.5m3, so the calculated volume is:
V"=2.16+0.5=2.66m3

From the above, the cleaning tank can choose a volume of 3m3.

Adjustable Street Light

The composition of adjustable street light:
1. Adjustable street light poles, lamp holders (light sources), battery panels, batteries, etc.
2. Pipelines and other materials needed to be laid for old street lamps. ·

Features of adjustable street lights:

Adjustable street light outdoor is a new type of road lighting facility. It uses crystalline silicon solar cells for power supply, maintenance-free valve-regulated sealed batteries to store electrical energy, ultra-bright LED lamps as light sources, and is controlled by an intelligent charge-discharge controller. It has the advantages of simple installation, less investment, good safety performance, energy saving and environmental protection, etc. It is a street lamp used to replace traditional public electric lighting.


Adjustable Street Light,Adjustable Street Light Outdoor,Adjustable Street Lights,Adjustable Street Light Yard

WOSEN LIGHTING TECHNOLOGY LIMITED , https://www.wosenled.com